The Readout
IEC 60601-1 harmonised, CRA reporting live, memory under pressure
IEC 60601-1 joins the harmonised list under the MDR, Cyber Resilience Act reporting has started, the AI Act sets 2 December for marking generated content, and the memory shortage weighs on bills of materials.
01 — Medical electrical standards
IEC 60601-1 cited in the Official Journal under the MDR
To anticipateDeadline: December 15, 2027 (J-385)Concerns: medical device maker
Implementing Decision (EU) 2026/1231, published in the Official Journal on 17 June 2026, adds EN 60601-1:2006 with amendment A13:2024 to the list of harmonised standards under Regulation (EU) 2017/745. For medical electrical equipment, applying this version now gives a presumption of conformity with the corresponding general safety requirements.
The same decision updates several parts of ISO 10993 (biocompatibility), with a transition until 15 December 2027 for parts 12, 17 and 23. The IEC lists the fourth edition of IEC 60601-1 for April 2029: edition 3.2 remains the reference for ongoing projects.
Check that your technical documentation cites EN 60601-1:2006/A13:2024 and that the test report matches this consolidated version. For a project certified after 2029, follow the fourth-edition work from the design stage.
02 — Product regulation
Cyber Resilience Act: reporting has started
Action requiredDeadline: December 11, 2027 (J-381)Concerns: connected product, investor, acquirer
Since 11 September 2026, manufacturers of products with digital elements must report actively exploited vulnerabilities and severe incidents to ENISA, through its single reporting platform opened the same day: early warning within 24 hours, notification within 72 hours, final report within 14 days of a fix being available.
Medical devices covered by the MDR and IVDR remain outside the CRA. Meanwhile, the targeted MDR and IVDR revision proposed in December 2025 is moving slowly: nearly 800 amendments were tabled in Parliament, a vote is expected in early 2027 and a final text not before late 2027.
For a non-medical connected product, you now need a vulnerability monitoring procedure and a decision chain able to meet the 24-hour clock. For a medical device, no new obligation yet, but the revision is worth following.
03 — AI and business tools
AI Act: marking generated content by 2 December
Action requiredDeadline: December 2, 2026 (J-7)Concerns: business using AI
The Article 50 transparency obligations have applied since 2 August 2026: tell people they are dealing with AI, disclose manipulated content. For generative AI systems already on the market, generated content must be marked by 2 December 2026 at the latest.
The omnibus regulation has however postponed high-risk obligations: 2 December 2027 for Annex III uses (recruitment, credit…), 2 August 2028 for AI built into regulated products.
If your company publishes AI-generated text, images or voice, check within a month that the tool marks them, and that your interfaces disclose the use of a conversational assistant.
04 — Electronics and due diligence
Memory: the AI-driven shortage is settling in
To anticipateConcerns: medical device maker, connected product, investor, acquirer
AI data-centre demand is absorbing memory output. Manufacturers are shifting lines to high-bandwidth memory, at the expense of conventional DRAM and NAND. Distributor Luminovo reported as early as February 2026 price rises of 80 to 90% in a quarter and lead times sometimes beyond a year, with no relief expected before late 2027 or 2028.
For equipment built in small series, memory becomes a risk component just like an end-of-life part: price, allocation and availability of older generations.
Flag single-source memory parts in your bills of materials and prepare qualified alternatives. In due diligence, a bill of materials' exposure to memory and end-of-life parts is now a valuation point in its own right.
Indicative summary based on public sources, as of the publication date. Not legal advice.
Want to discuss it for your product?
Design and verification→Medical device cybersecurity and AI→Technical due diligence and reverse engineering→Free 30-min call →A project to move forward? Let's talk.
First 30-minute call free, no commitment. Three lines are enough: the topic, the stage, the deadline. Reply within two business days.
Use the contact form →Please do not send confidential documentation before a non-disclosure agreement has been signed.